Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.527
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
3.
J Cardiothorac Surg ; 19(1): 176, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576022

RESUMO

BACKGROUND: Mechanical heart valve replacement is a standard treatment for severe valvular disorders. The use of mono-leaflet valves has decreased recently. Recognizing the echocardiographic features of mono-leaflet and bileaflet valves is crucial for accurate complication diagnosis and proper management. CASE PRESENTATION: A 65-year-old female with mono-leaflet mitral and bileaflet tricuspid valves underwent an echocardiographic assessment. This simple educational case provides a unique opportunity to compare the echocardiographic features of these valves within a single patient. CONCLUSION: There is a crucial need for clinicians, particularly those in training, to differentiate between mono-leaflet and bileaflet mechanical heart valves adeptly. With mono-leaflet valves decreasing in prevalence, proficiency in recognizing the echocardiographic nuances of each type is imperative. Failure to do so may result in misdiagnoses and inappropriate management. This underscores the significance of continuous education and vigilance in echocardiographic assessments to ensure optimal patient care.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral , Feminino , Humanos , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Ecocardiografia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Desenho de Prótese
5.
JACC Cardiovasc Interv ; 17(8): 1073-1075, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658125
6.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38603618

RESUMO

OBJECTIVES: Recurrence of tricuspid regurgitation (TR) after tricuspid annuloplasty can occur in cases where a dilated right ventricle exists and subsequent leaflet tethering follows. We previously reported a new technique of the right ventricular papillary muscle approximation (RV-PMA) for functional TR associated with leaflet tethering. The objective of this study is to elucidate the mid-term outcomes and evaluate the durability of RV-PMA. METHODS: Between January 2014 and March 2023, we applied RV-PMA in 20 patients of advanced functional TR with severe leaflet tethering. The indication of the technique was severe TR with leaflet tethering height >8 mm, and/or a right ventricular end-diastolic diameter >45 mm. The patients were followed up with echocardiography before discharge and at annual interval thereafter. RESULTS: There was no perioperative mortality. In the echocardiography performed before discharge, TR was decreased to mild or less in 85%, and a significant improvement in right ventricular end-diastolic diameter and tethering height were achieved (53-45 mm and 11.1-4.4 mm, respectively). Furthermore, during the median 3-year follow-up period, TR was kept controlled mild or less in 80% of the cases. CONCLUSIONS: RV-PMA is considered to be a safe, effective and durable technique as an additional approach for tricuspid annuloplasty.


Assuntos
Ventrículos do Coração , Músculos Papilares , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Músculos Papilares/cirurgia , Músculos Papilares/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Ventrículos do Coração/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Resultado do Tratamento , Ecocardiografia , Anuloplastia da Valva Cardíaca/métodos , Estudos Retrospectivos , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Índice de Gravidade de Doença , Seguimentos
7.
JACC Cardiovasc Interv ; 17(7): 837-858, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599687

RESUMO

Severe tricuspid regurgitation (TR) is a progressive condition associated with substantial morbidity, poor quality of life, and increased mortality. Patients with TR commonly have coexisting conditions including congestive heart failure, pulmonary hypertension, chronic lung disease, atrial fibrillation, and cardiovascular implantable electronic devices, which can increase the complexity of medical and surgical TR management. As such, the optimal timing of referral for isolated tricuspid valve (TV) intervention is undefined, and TV surgery has been associated with elevated risk of morbidity and mortality. More recently, an unprecedented growth in TR treatment options, namely the development of a wide range of transcatheter TV interventions (TTVI) is stimulating increased interest and referral for TV intervention across the entire medical community. However, there are no stepwise algorithms for the optimal management of symptomatic severe TR before TTVI. This article reviews the contemporary assessment and management of TR with addition of a medical framework to optimize TR before referral for TTVI.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Qualidade de Vida , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
12.
Echocardiography ; 41(4): e15804, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38578295

RESUMO

A 60-year-old man presented with breathlessness. Nearly four decades previously, he had required three operations for Staphylococcus aureus infective endocarditis of the tricuspid valve and had received a bioprosthetic valve. He had critical tricuspid bioprosthesis stenosis which was treated successfully by valve-in-valve transcatheter tricuspid valve replacement using a balloon-expandable transcatheter heart valve. One year after intervention, the patient is well with no tricuspid valve stenosis or regurgitation.


Assuntos
Bioprótese , Endocardite Bacteriana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Estenose da Valva Tricúspide , Masculino , Humanos , Pessoa de Meia-Idade , Adulto , Bioprótese/efeitos adversos , Constrição Patológica , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/cirurgia , Resultado do Tratamento , Desenho de Prótese , Falha de Prótese
13.
J Am Heart Assoc ; 13(8): e032929, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38563385

RESUMO

BACKGROUND: TRI-SCORE was recently developed in Europe as a risk model for predicting in-hospital death after isolated tricuspid valve surgery. We aimed to validate TRI-SCORE in an Asian population and investigate its value for predicting long-term outcomes. METHODS AND RESULTS: The TRI-SCORE was calculated for 202 patients (65±11 years, 61% women, 81% functional tricuspid regurgitation) who underwent isolated tricuspid valve surgery for severe tricuspid regurgitation at 2 Korean centers and was based on 8 parameters: age, New York Heart Association class, right-sided heart failure signs, furosemide daily dose, glomerular filtration rate, bilirubin, left ventricular ejection fraction, and moderate/severe right ventricular dysfunction. The primary outcome was all-cause death during follow-up; the secondary outcome was in-hospital death. During a median follow-up duration of 50 (interquartile range, 21-82) months after isolated tricuspid valve surgery, 23 (11.4%) patients experienced the primary outcome, and 7 (3.5%) patients experienced the secondary outcome. Observed all-cause death and in-hospital death increased by up to 50% in those with higher scores. Patients with the primary outcome had a higher TRI-SCORE (4.5±2.4 versus 2.9±2.1; P=0.001) than those without. The TRI-SCORE showed a significant association with the primary outcome (concordance index, 0.77, cutoff value, 4) and in-hospital death (area under the curve, 0.84; cutoff value, 3). Using the Kaplan-Meier analysis, patients with a high TRI-SCORE exhibited a poor outcome for all-cause death at follow-up (log-rank P<0.001) and in-hospital death (log-rank P=0.004). CONCLUSIONS: TRI-SCORE was validated in an Asian population and helped predict long-term outcomes after isolated tricuspid valve surgery.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Resultado do Tratamento , Volume Sistólico , Mortalidade Hospitalar , Função Ventricular Esquerda , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Retrospectivos
16.
J Cardiovasc Electrophysiol ; 35(5): 1017-1025, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501386

RESUMO

Tricuspid regurgitation (TR) secondary to cardiac implantable electronic devices (CIEDs) has been well documented and is associated with worse cardiovascular outcomes. A variety of mechanisms have been proposed including lead-induced mechanical disruption of the tricuspid valvular or subvalvular apparatus and pacing-induced electrical dyssynchrony. Patient characteristics such as age, sex, baseline atrial fibrillation, and pre-existing TR have not been consistent predictors of CIED-induced TR. While two-dimensional echocardiography is helpful in assessing the severity of TR, three-dimensional echocardiography has significantly improved accuracy in identifying the etiology of TR and whether lead position contributes to TR. Three-dimensional echocardiography may therefore play a future role in optimizing lead positioning during implant to reduce the risk of CIED-induced TR. Optimal lead management strategies in addition to percutaneous interventions and surgery in alleviating TR are very important.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Fatores de Risco , Resultado do Tratamento , Ecocardiografia Tridimensional
18.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38450808

RESUMO

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Assuntos
Remoção de Dispositivo , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico , Masculino , Feminino , Remoção de Dispositivo/efeitos adversos , Idoso , Resultado do Tratamento , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Desfibriladores Implantáveis , Fatores de Tempo , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização Cardíaca
19.
J Am Heart Assoc ; 13(6): e032999, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38471826

RESUMO

Tricuspid regurgitation is a common yet clinically complex problem, traditionally managed with diuretic therapy with no observable mortality benefit. Older studies on surgical intervention observed poor outcomes; however, this clinical reasoning predates current surgical approaches and novel transcatheter technology. The tricuspid apparatus is a complex structure that poses a technical challenge for surgeons and interventional cardiologists. Recent advances in surgical techniques and transcatheter therapy, particularly edge-to-edge repair devices, have demonstrated promising results for safety, reduction in tricuspid regurgitation, and improving quality of life. We review the clinical, imaging, and hemodynamic findings that characterize patients who should be considered for intervention, alongside the rapidly evolving approaches to interventional management.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...